Over the years, AIMIX group has been designing, producing and servicing concrete pump products to make your concrete pumping more efficient and safer, as well as maximize your profits. The equipment can be powered by electric or diesel engine to fit different job sites and job requirements. Besides, you can choose from our wide range of products from mixer pump, boom pump to trailer pump and truck mounted pump. We are always at the service of your concrete conveying needs.

Supply Scope of AIMIX Cement Concrete Pump
We supply different types of concrete pump for sale, each with optimum design and robust construction to ensure high performance, reliability and durability.
Concrete trailer pump
- Trailer pump is mounted on movable tires, which can be dragged to the job site using a trailer. It requires concrete placing hoses that are manually attached to the outlet of the machine. Those linked hoses can lead to wherever the concrete needs to be placed.
- Power source: electric or diesel engine
- Popular models: ABT60D, ABT80D, ABT90D, ABT60C, ABT80C, ABT90C
- Application: for conveying concrete mixes in building construction, bridge construction, tunnel construction, etc.
- Advantages: relatively low operating costs, greater conveying height (compared to boom pump), easy maintenance and low maintenance costs.
Concrete mixer with pump
- Concrete mixer and pump is a cost-effective and small pump machine that combines concrete mixer and pump in one. That is, it can not only pump concrete, but mix it. It can pump concrete to the height of 80-100m and the length of 150-300m. In addition, the pumping equipment can be designed with a concrete drum mixer or twin-shaft compulsory mixer depending on your requirements.
- Power source: electric power or diesel
- Applications: ideal for small construction projects and rural construction
- Popular models: ABJZ30D, ABJZ30C, ABJZ40D, ABJS40D, ABJZ40C, ABJS40C
- Features: pumping at small volumes, small size, low power consumption, low cost
Concrete boom pump

- Boom pump is a flexible and mobile pump machine designed with a boom to place concrete accurately. The placing boom length can be 18m, 24m, 25m, 37m, 42m and 50m.
- Application: suitable for transferring concrete for large construction projects such as high-rise building construction, highway construction and overpass construction.
- Features: capable of pumping at very high volumes, saving labor with the placing boom, high level of flexibility, faster pumping speed
Truck mounted pump

- Mounted on a truck, the pump can move from one job site to another easily and quickly. It can reach a great conveying height using high-pressure pipe.
- Application: ideal for urban construction
- Advantages: high level of mobility, easy transportation, smaller occupying area, more affordable than a boom pump, low operating costs
Selection of Power Source for Your Pump
Our pump can be powered by electricity or diesel engine. The selection of power source is determined by several factors, including user’s preference, the available infrastructure and financial considerations.
The difference between electric and diesel concrete pump:
- Electric pump: simple structure, reliable performance, low operating cost
- Diesel pump: suitable for job sites where the electric power is unavailable or difficult to obtain. Diesel pump is more expensive than an electric one as it is built with diesel engine and other accessories. Therefore, it also requires more maintenance care and more maintenance costs.
If you are unsure as to which equipment is right for the job, please contact us at any time. We are very pleased to help you identify the most appropriate pump equipment for your application.
Cases For Your Kind Reference



Specifications
Click to view the pump specifications you need
Concrete mixer pump
ABJZ30C
Items | Units | Perameters | |
ABJZ30C | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 30 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.35 | |
Max.concrete pumping pressure(H./L.) | MPa | 10 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ140×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ150 | |
Winding motor power | KW | Hydraulic motor | |
Stir the motorPower | KW | Hydraulic motor | |
Water pump motor powe | KW | Hydraulic motor | |
Power system | Diesel engine model | ||
Electrical engineering power | KW | 37 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 26 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 260 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/300 |
Max. aggregate diameter | mm | Slick/scree:10/20 | |
Inside diameter of delivering pipe | mm | Φ100 | |
Dimensions:length×width×height | mm | 4500x1750x1600 | |
Total weight | kg | 3000 |
ABJZ30D
Items | Units | Perameters | |
ABJZ30D | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 30 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.35 | |
Max.concrete pumping pressure(H./L.) | MPa | 10 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ140×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ150 | |
Winding motor power | KW | 5.5 | |
Stir the motorPower | KW | 4.5 | |
Water pump motor powe | KW | 0.55 | |
Power system | Diesel engine model | ||
Electrical engineering power | KW | 37 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 26 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 260 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/300 |
Max. aggregate diameter | mm | Slick/scree:10/20 | |
Inside diameter of delivering pipe | mm | Φ100 | |
Dimensions:length×width×height | mm | 4500x1750x1600 | |
Total weight | kg | 3000 |
ABJZ40C
Items | Units | Perameters | |
ABJZ40C | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.45 | |
Max.concrete pumping pressure(H./L.) | MPa | 10 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ180×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ150 | |
Winding motor power | KW | Hydraulic motor | |
Stir the motorPower | KW | Hydraulic motor | |
Water pump motor powe | KW | Hydraulic motor | |
Power system | Diesel engine model | Weichai | |
Electrical engineering power | KW | 82 | |
Rotate speed | r/min | 2200 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 32 | |
Mixing system pressure | MPa | 6 | |
Capacity of oil tank | L | 350 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 600x2300x3150 | |
Total weight | kg | 4500 |
ABJZ40D
Items | Units | Perameters | |
ABJZ40D | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.45 | |
Max.concrete pumping pressure(H./L.) | MPa | 10 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ180×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ150 | |
Winding motor power | KW | 5.5 | |
Stir the motorPower | KW | 4.5 | |
Water pump motor powe | KW | 0.55 | |
Power system | Diesel engine model | ||
Electrical engineering power | KW | 45 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 26 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 370 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 4200x2300x3150 | |
Total weight | kg | 4500 |
ABJS40C with JS500
Items | Units | Perameters | |
ABJS40C | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.5 | |
Max.concrete pumping pressure(H./L.) | MPa | 8 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ180 | |
Winding motor power | KW | Hydraulic motor | |
Stir the motorPower | KW | Hydraulic motor | |
Water pump motor powe | KW | Hydraulic motor | |
Power system | Diesel engine model | Weichai | |
Electrical engineering power | KW | 129 | |
Rotate speed | r/min | 2200 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 32 | |
Mixing system pressure | MPa | 6 | |
Capacity of oil tank | L | 350 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 7500x2300x3150 | |
Total weight | kg | 5000 |
ABJS40D with JS500
Items | Units | Perameters | |
ABJS40D | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.5 | |
Max.concrete pumping pressure(H./L.) | MPa | 8 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ180 | |
Winding motor power | KW | 5.5 | |
Stir the motorPower | KW | 18.5 | |
Water pump motor powe | KW | 0.75 | |
Power system | Diesel engine model | ||
Electrical engineering power | KW | 45 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 26 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 370 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 4200x2300x3150 | |
Total weight | kg | 4500 |
ABJS40C with JS750
Items | Units | Perameters | |
ABJS40C | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.75 | |
Max.concrete pumping pressure(H./L.) | MPa | 8 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ180 | |
Winding motor power | KW | Hydraulic motor | |
Stir the motorPower | KW | Hydraulic motor | |
Water pump motor powe | KW | Hydraulic motor | |
Power system | Diesel engine model | Weichai | |
Electrical engineering power | KW | 129 | |
Rotate speed | r/min | 2200 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 32 | |
Mixing system pressure | MPa | 6 | |
Capacity of oil tank | L | 350 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 7500x2300x3150 | |
Total weight | kg | 5500 |
ABJS40D with JS750
Items | Units | Perameters | |
ABJS40D | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40 |
Mixer rated feed capacity | m3 | 0.56 | |
Mixer rated discharge capacity | m3 | 0.75 | |
Max.concrete pumping pressure(H./L.) | MPa | 8 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1000 | |
Hopper capacity | L | 400 | |
Outlet diameter | mm | Φ180 | |
Winding motor power | KW | 7.5 | |
Stir the motorPower | KW | 30 | |
Water pump motor powe | KW | 0.75 | |
Power system | Diesel engine model | ||
Electrical engineering power | KW | 45 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 28 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 370 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 6000x2300x3150 | |
Total weight | kg | 5000 |
Trailer pump
ABT40C
Items | Units | Perameters | |
ABT40C | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40/26 |
Max.concrete pumping pressure(H./L.) | MPa | 10/7.6 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ180×1200 | |
Hopper capacity x feeding height | L/mm | 400/1100 | |
Outlet diameter | mm | Φ150 | |
Power system | Diesel engine model | Weifang Delier 6105ZB | |
Electrical engineering power | KW | 82 | |
Rotate speed | r/min | 2100 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 32 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 370 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 5000x1850x1700 | |
Total weight | kg | 4500 |
ABT40D
Items | Units | Perameters | |
ABT40D | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 40 |
Max.concrete pumping pressure(H./L.) | MPa | 10 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ180×1200 | |
Hopper capacity x feeding height | L/mm | 400/1100 | |
Outlet diameter | mm | Φ100 | |
Electrical engineering power | KW | 45 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 28 | |
Mixing system pressure | MPa | 8 | |
Capacity of oil tank | L | 370 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 120/500 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 4500x1750x1600 | |
Total weight | kg | 3200 |
ABT60C
Items | Units | Perameters | |
ABT60C | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 67/45 |
Max.concrete pumping pressure(H./L.) | MPa | 13/7 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1650 | |
Hopper capacity x feeding height | L/mm | 800/1400 | |
Outlet diameter | mm | Φ180 | |
Power system | Diesel engine model | Wechai | |
Electrical engineering power | KW | 129 | |
Rotate speed | r/min | 2200 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 32 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 370 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 180/800 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 5800x2000x1750 | |
Total weight | kg | 6500 |
ABT60D
Items | Units | Perameters | |
ABT60D | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 60/36 |
Max.concrete pumping pressure(H./L.) | MPa | 13/7 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1650 | |
Hopper capacity x feeding height | L/mm | 800/1100 | |
Outlet diameter | mm | Φ180 | |
Electrical engineering power | KW | 90 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 28 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 560 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 160/800 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 4500x1750x1600 | |
Total weight | kg | 6000 |
ABT80C
Items | Units | Perameters | |
ABT80C | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 84/45 |
Max.concrete pumping pressure(H./L.) | MPa | 16/11 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1800 | |
Hopper capacity x feeding height | L/mm | 800/1400 | |
Outlet diameter | mm | Φ180 | |
Power system | Diesel engine model | Wechai | |
Electrical engineering power | KW | 176 | |
Rotate speed | r/min | 2200 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 32 | |
Mixing system pressure | MPa | 6-8 | |
Capacity of oil tank | L | 580 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 200/800 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 6300x2100x2350 | |
Total weight | kg | 6900 |
ABT80D
Items | Units | Perameters | |
ABT80D | |||
whole performance of machine | Max. theo. concrete output(L./H) | M3/h | 86/45 |
Max.concrete pumping pressure(H./L.) | MPa | 16/11 | |
Distribution valve type | S Valve | ||
Concrete cylinder diameter×stroke | mm | Φ200×1800 | |
Hopper capacity x feeding height | L/mm | 800/1100 | |
Outlet diameter | mm | Φ180 | |
Electrical engineering power | KW | 90 | |
Rotate speed | r/min | 1480 | |
Hydraulic system | Circuit type | Open circuit | |
Pumping system pressure | MPa | 32 | |
Mixing system pressure | MPa | 14 | |
Capacity of oil tank | L | 580 | |
Other parameters | Max. Theoretical Vertical/Horizontal Conveying Distance | m | 200/800 |
Max. aggregate diameter | mm | Slick/scree:40/50 | |
Inside diameter of delivering pipe | mm | Φ125 | |
Dimensions:length×width×height | mm | 6300x2100x2250 | |
Total weight | kg | 6300 |
Features That Make A Difference
- Water cooling system is designed for better heat dissipation effect, thereby increasing the service life and working efficiency of the hydraulic components.
- Accessories are sourced from international renowned brands which are reliable, easy to access, have low failure rate and long service life. For example, hydraulic hoses are sourced from Manuli, the main electric components from Schneider and PLC from Omron.
- Remote control makes the operation safer and more convenient.
- Automatic centralized lubrication system to ensure effective lubrication during operation.
- Reverse pumping function helps to solve the pipe plugging problem in time.
Interested in our concrete pump or want the best prices?
Concrete Pumping System
Pumping mechanism – it consists of two main oil cylinders, a water tank, reversing device, two concrete cylinders, two concrete pistons, hopper, S valve, swing arm, two swing cylinders and discharge port.

Power and hydraulic system – it consists of electric motor/diesel engine, hydraulic tank, hydraulic pump, piping system, reversing valve, hydraulic cylinder & motor, cooling system and accumulator.

Electric control system – PLC control system with one-click repair function

Lubrication system – lubricating various parts with an automatic lubrication pump

Q&A
1. How does a concrete pump work?
The machine uses high pressure to continuously transfer concrete mixes along pipes. Specifically speaking, high-pressure oil outputted by the main oil pump is distributed into the main cylinder through the sequence valve, so that the piston is pushed forward and backward, thereby allowing concrete to enter and exit the concrete cylinders. At the same time, the swing cylinder drives the swing arm under high pressure oil, thereby driving the S valve to switch between the exits of the two concrete cylinders. Through the continuous reciprocating motion of the concrete cylinders and the switching of the S valve, continuous suction and extrusion of concrete is realized, thus completing the entire pumping process.
2. How much is a concrete pump?
The pump cost is determined by several factors, including your required output capacity, power source, maximum aggregate diameter, conveying distance and other configurations you require. You can fill out the contact form or send us an email to let us know your required concrete pump specification, and then we will provide you with the most suitable and economical pump for your job.
3. What should I do if the hoses are stuck by stones during pumping?
You can use reverse pumping function to repeatedly press the pumping and reverse pumping states until it returns to normal.

Why Choose Us?
AIMIX wide range of pump machines give you optimum performance and maximum productivity. Superior quality, competitive price and perfect service make us a trusted name in the concrete pumping industry. What’s more, we provide a comprehensive after-sales service that comprise the equipment installation, commissioning, staff training, free technical advice, 12-month warranty and spare parts service for our clients to make sure they run smoothly and quickly.
If you are looking for a dependable concrete pump manufacturer and supplier in China, come to AIMIX group!